Fire & Life Safety
SYSTEMS › Security & Life SafetyCore

Fire & Life Safety

Early detection, safe evacuation, uninterrupted life security.

People First

Detect fire risk at the first moment, evacuate everyone safely

Every second lost in fire and gas leakage is critical for the safety of life and property. FAV Technology's fire and life safety systems; It detects the risk early, transmits the alarm to the right point and keeps escape routes safe with smoke control, emergency lighting and guidance. We carry out projects in hotels, hospitals, shopping malls, offices, residential and industrial facilities in accordance with the regulations and EN 54 standards; We design the system to work on a scenario basis with announcements, access control and building automation.
Exact detection of the point where the fire occurred with the addressable structure
Multiple sensors (smoke, heat, gas) for early detection
Stair/elevator pressurization and smoke exhaust scenarios in case of fire
Voice evacuation, emergency lighting and door scenarios
SUBSYSTEMS

Hardware and Software Layers that Make Up the System

Each component works with a certified, redundant and central integration infrastructure at international standards.

Addressable Fire Detection and Alarm
01 · Exact Location of FireFAV Enterprise Standard
Exact Location of Fire

Addressable Fire Detection and Alarm

Each detector and fire alarm button receives a separate address; At the time of alarm, the exact location of the fire is shown on the panel and monitoring screen. With smoke, heat and multi-sensor detectors, fire is detected while it is still in its infancy. Alarm; Automatically initiates voice evacuation, door release and elevator scenarios.

  • EN 54-2 and EN 54-4 certified interactive addressable fire panels
  • Modular capacity supporting hundreds of addresses on the loop line
  • Line safety with detectors with short circuit isolators
  • Point alarm tracking on the building plan with graphic monitoring software
Gas Detection
02 · Against Invisible RiskFAV Enterprise Standard
Against Invisible Risk

Gas Detection

Flammable and toxic gas leaks in kitchens, boiler rooms, indoor parking lots and technical areas are detected early. With the alarm, the gas valve is automatically closed, ventilation is activated and the relevant personnel is informed. In closed car parks, ventilation is activated gradually depending on the carbon monoxide level.

  • Natural gas, LPG, methane and carbon monoxide (CO) sensors
  • Ex-proof ATEX certified models for explosive atmospheres
  • Instant closing relays for solenoid valves and fire dampers
  • Gradual ventilation jet fan control according to threshold level
Smoke Control and Evacuation
03 · Escape Routes SmokelessFAV Enterprise Standard
Escape Routes Smokeless

Smoke Control and Evacuation

In case of fire, staircases and elevator shafts are pressurized to prevent smoke from entering escape routes; smoke exhaust fans and dampers are controlled automatically. This way, evacuation routes remain usable, saving valuable time for fire brigade intervention. All scenarios are tested and documented in the field during commissioning.

  • Positive pressurization of stairs and elevator shafts in case of fire
  • Control of smoke discharge flaps and motorized smoke dampers
  • Fire zone isolation according to fire scenario
  • Bi-directional integration with BMS and HVAC systems
Emergency Lighting and Guidance
04 · Right Direction in the DarkFAV Enterprise Standard
Right Direction in the Dark

Emergency Lighting and Guidance

In case of power outage or fire, escape routes and exits are automatically illuminated. Direction fixtures direct users to the nearest and safest exit. Luminaire placement is designed in accordance with regulations and escape plan.

  • Full compliance with EN 1838 and EN 50172 emergency lighting norms
  • 3-hour independent battery powered or central battery powered luminaires
  • Photoluminescent escape guidance pictograms
  • Minimum 1 lux floor lighting assurance in escape corridors
Emergency Lighting with Central Test and Monitoring
05 · Tested, ReportedFAV Enterprise Standard
Tested, Reported

Emergency Lighting with Central Test and Monitoring

Emergency lighting fixtures are periodically self-tested; Battery and lamp malfunctions are instantly seen from the center. Test records that must be kept in accordance with the regulation are reported automatically. Maintenance time spent checking fixtures one by one and inspection risk are reduced.

  • DALI based or addressable central battery management panel
  • Automatic execution of function and duration tests based on a calendar
  • Detection of faulty lamp or exhausted battery points on the map
  • Automatic report output ready for official fire inspections
Automatic Extinguishing Systems
06 · Automatic InterventionFAV Enterprise Standard
Automatic Intervention

Automatic Extinguishing Systems

Sprinkler and gas extinguishing systems work integrated with the fire detection system and intervene in fire automatically. Gas extinguishing solutions that do not damage the equipment are applied in critical volumes such as server rooms, archives and electrical rooms.

  • FM-200, Novec 1230 and Inert gas clean extinguishing systems
  • Micro extinguishing tubes inside the electrical panel
  • Sprinkler flow switch and valve monitoring
  • Preventing false discharge with double zone cross-zone detection
BENEFITS

Advantages of Fire and Life Safety Systems

Fire & Life Safety Its investment directly reduces operational costs while increasing infrastructure security and efficiency.

Early Detection

Fire and gas risks are detected at the initial stage.

Safe Evacuation

Voice announcement, emergency lighting and guidance get people out safely.

Automatic Scenarios

Doors, elevators and fans are activated automatically upon alarm.

Regulatory Compliance

Systems are designed and documented in accordance with regulations and EN standards.

WHY FAV?

Why FAV Technology?

Not a product vendor, but a turnkey integration and sustainability partner.

Reliable Brands, Right Choice

We select certified products from world brands such as Honeywell and Panasonic according to the risk class of your building and regulatory requirements; We build reliable and future-proof systems.

  • Honeywell, Panasonic, Morley-IAS, Notifier ecosystem
  • LPCB, VdS, UL and EN 54 international quality approvals
  • Project planning with manufacturer-approved certified engineer staff
AUTHORIZED BUSINESS PARTNERS AND MANUFACTURERS:
honeywellpanasonicbosch
FREQUENTLY ASKED QUESTIONS

Frequently Asked Questions

Fire & Life Safety Questions about infrastructure, standards and corporate application processes.

Detects fire and gas risks early and transmits the alarm; They are integrated systems that provide safe evacuation of people with smoke control, emergency lighting and guidance.
RELATED SOLUTIONS

Solutions Included in This System

Systems do not stand alone; It works together on the axes of operational needs.

Basic Infrastructure is Included in All Our ProjectsSystem room and network, CCTV, access control, fire detection, voice alarm, uninterruptible power and 24/7 maintenance. It is the sector-specific systems that make the difference.
Review the Engineering Process →
FREE TECHNICAL DISCOVERY & CONSULTANCY

Let's plan a survey for your project

Let our expert team examine your building on site and design the fire detection, smoke control and emergency lighting infrastructure in accordance with the regulations.